The “bootstrap” step — using surviving ToF pixels to find the correct metric scale for learned depth.
The equation
Per frame, over pixels where ToF confidence ≥ 0.5:
\[s = \text{median}\left(\frac{d_{\text{tof}}}{\hat{d}}\right)\]- $d_{\text{tof}}$ — hardware ToF depth at valid pixels
- $\hat{d}$ — raw student-predicted depth at the same pixels
- $s$ — scalar scale factor, applied to the entire student depth map
After computing s, the student depth gets re-scaled: d_student_scaled = s · d_hat. The scaled student depth then participates in Confidence-Gated Fusion.
Why median, not mean
Three reasons:
- Robust to outliers. A handful of misread ToF pixels (specular spike, edge case at close range) don’t corrupt the estimate. Median is the natural robust statistic for ratio-of-noisy-signals.
- Symmetric in the ratio direction. If the student systematically over-predicts on one half of the frame and under-predicts on the other, the median picks the central tendency without being pulled by either tail.
- Computationally trivial. No iterative fitting, no convergence concerns — just a sort. Runs at >100 Hz on the Jetson without optimization.
Why this works at 22% pixel coverage
The surviving 22% of ToF pixels per frame is more than enough sample size for a median estimate. Ten valid samples is enough; we typically have tens of thousands. The bottleneck isn’t sample count, it’s whether the surviving pixels span the depth range — and they generally do, because failures are surface-specific (see ToF Failure Modes) rather than depth-specific.
The valid samples cluster on matte walls, fabric, and rough surfaces — but those surfaces appear at varying depths across a typical corridor frame. Near walls, mid-field surfaces, and far walls all contribute valid samples. The median ratio is robust across that depth range.
Why this is needed in the first place
The student model (EfficientViT-B1, see the V9 page for the deployment checkpoint) outputs depth in a learned scale. That scale is approximately metric — the model trains against DA3-Metric-Large which is calibrated to meters — but per-frame absolute scale can drift due to:
- The training distribution’s average focal length differing from the deployment camera
- The deployment camera’s exact intrinsics not matching the training calibration
- Frame-to-frame variation in which structures are visible (a frame dominated by far-field gets a different absolute scale than a near-field frame)
The median-scale step corrects all three at once, per frame, using the surviving sensor pixels. Absolute scale doesn’t have to be perfect because the calibration fixes it.
What the model has to get right (since it doesn’t have to get scale right)
If absolute scale gets corrected per frame, the model only has to get the shape of the depth map right:
- Spatial structure of obstacles (where the wall is, where the floor ends)
- Relative depth between regions (which obstacle is closer)
- Smoothness within regions (no holes or spikes within a flat surface)
- Sharpness at boundaries (depth discontinuity at object edges)
This is why the project doesn’t lean too hard on raw RMSE numbers. The absolute meter-error matters less than the structural correctness, because median-scale alignment is part of the runtime.
Specification and deployment
The median-scale equation as written is the formal specification, and is computed explicitly by the offline evaluation pipeline (calibration_sensitivity.py). The on-vehicle deployment realization applies the same principle implicitly: confidence-gated substitution achieves the same costmap geometry as scale-then-substitute under the deployment regime, which avoids an explicit per-frame median computation in the latency-critical path.
The two implementations are operationally equivalent within the calibration sensitivity bound reported in the calibration study. See Specification and Deployment Realization for the full mapping between the two pipelines.
Related
- Bootstrap Perception — the project-level idea this calibration step is part of
- Confidence-Gated Fusion — what happens after the scale is computed
- Calibration sensitivity study — how the calibration set size affects accuracy